Blood Collection Tubes

Serum Tube

°@

Serum Tube
Details°G
Material: PET/GLASS, GLASS/PET
Additive: Glot Additive
Specimen: Serum
Specification: 13*75mm, 13*100mm, 16*100mm
Draw Volume:  1-10ml
Max. Vacuum Degree Tolerance: °”10%
Notes: Centrifuge for 5-10 minutes after 15-30 minutes' coagulation

°@

ESR Tube

°@

ESR Tube
Details°G
Material: PET/GLASS, GLASS/PET
Additive: 3.8% Sodium Citrate (1:4)
Specimen: Whole Blood
Specification: 13*75mm, 13*100mm, 16*100mm
Draw Volume:  1-10ml
Max. Vacuum Degree Tolerance: °”10%
Notes: Invert the tube for 6-8 times gently

°@

PT Tube

°@

PT Tube
Details°G
Material: PET/GLASS, GLASS/PET
Additive: 3.8% Sodium Citrate (1:9)
Specimen: Whole Blood or Plasma
Specification: 13*75mm, 13*100mm
Draw Volume:  1-10ml
Max. Vacuum Degree Tolerance: °”10%
Notes: Invert the tube for 6-8 times gently

°@

Glucose

°@

Glucose Tube
Details°G
Material: PET/GLASS, GLASS/PET
Additive: Sodium Fluoride & Potassium Oxalate
Specimen: Plasma
Specification: 13*75mm, 13*100mm
Draw Volume:  1-10ml
Max. Vacuum Degree Tolerance: °”10%
Notes: Iinvert tube 6 to 8 times gently/Iinvert

°@

SST Tube

°@

SST Tube
Details°G
Material: PET/GLASS, GLASS/PET
Additive: Gel & Clot Activator
Specimen: Serum
Specification: 13*75mm, 13*100mm, 16*100mm
Draw Volume:  1-10ml
Max. Vacuum Degree Tolerance: °”10%
Notes: Invert the tube for 6-8 times gently and centrifuge 5-10 minutes at 1200-1500g after 15-30 minutes°¶ complete coagulation

°@

Heparine Tube

°@

Heparine Tube
Details°G
Material: PET/GLASS, GLASS/PET
Additive: Draw required volume & invert the tube for 6-8 times gently
Specimen: Plasma
Specification: 13*75mm, 13*100mm, 16*100mm
Draw Volume:  1-10ml
Max. Vacuum Degree Tolerance: °”10%
Notes: Draw required volume & invert the tube for 6-8 times gently

°@

EDTA Tube

°@

EDTA Tube
Details°G
Material: PET/GLASS, GLASS/PET
Additive:EDTA K2, EDTA K3
Specimen: WHOLE BLOO
Specification: 13*75mm, 13*100mm, 16*100mm
Draw Volume:  1-10ml
Max. Vacuum Degree Tolerance: °”10%
Notes: Invert the tube for 6-8 times immediately after drawing blood, the inverting times should be increased accordingly if the temperature outside is higher than 35ĘJ.

°@

Plain Tube

Plain Tube
Details°G
Material: PET/GLASS, GLASS/PET
Additive: NO Additive
Specimen: Serum
Specification: 13*75mm, 13*100mm, 16*100mm
Draw Volume:  1-10ml
Max. Vacuum Degree Tolerance: °”10%
Notes: Centrifuge for 5-10 minutes after blood coagulation

°@

°@

°@

Weizhou International Co., Ltd

P. O. Box 1394 Kaohsiung City., Ltd

Tel : 886-7-7169249         Fax : 886-7-2134620

e-Mail : medical@weitronic.com.tw        e-Mail : shiu@ksts.seed.net.tw

http://www.weizhou.com.tw/medical/Index-export.htm

 

°@

       Back  Homepage             Back Medical Page

°@

°@

°@